Normally, an electronic thermostat in the United States is powered by a 24V AC power supply which comes from a 110V/24V power transformer. If you are not sure, always refer to the operating manual of your thermostat in your house before attempting to do any trouble shooting or replacement work.
As always, if you are not trained to handle electrical equipment, please get a qualified technician to do it. It is always a good idea to take a picture of the current heat pump thermostat wiring before you start removing them. In heat pump system, there are at least 8 wires that need to be connected to the thermostat for proper operation. Heat Pump Thermostat Wiring Diagram. Heat pump thermostat wiring - A typical wire color and terminal diagram As shown in the diagram, you will need to power up the thermostat and the 24V AC power is connected to the R and C terminals. The color of wire R is usually RED and C is BLACK. C is known as the common terminal.
These two connections will ensure that there is power to the thermostat that you are operating. The Y terminal is where the signal to the cooling air conditioner signal is connected. This terminal will call for the need to cool the room when the set temperature is lower than the room temperature. The G terminal is connected to the indoor fan which circulates the air in the room. The reversing valve is a device that reverses the flow of the refrigerant in the piping system. In most cases, the reversing valve is energized when running cool mode.
York Air Conditioner Wiring Guide
However, there are instances where the reversing valve is off when running cool mode. Therefore, it is important the check the manufacturer's specifications of the heat pump system that you are using before you can do a proper connection to the thermostat. The O terminal is used when the system that you are using has a reversing valve (or four way valve) which is turned on when running cooling mode. If the reversing valve is turned on when running heat mode, you will need to connect the reversing valve to B terminal.
Only one connection is active at any one time, that is either O or B terminal is used but not both. In some equipment, there is a 2nd stage cooling that helps to increase the cooling capacity of the room. In this case the terminal Y2 is usually used.
The color of the wire vary. Sometimes, there is a 2nd stage heating where additional heating is provided to supplement the primary heating system. This is usually installed in regions where extreme winter occurred. In this case the terminal W2 will be present. Some thermostat may have a feature called Emergency Heat where when set, it will shut off the heat pump. 2002 volkswagen passat service manual. It will then turn on the strip heat which becomes the primary source of heating. Learn cbse class 9. This feature should only be used for a while as the energy cost is usually higher than a heat pump system.
The terminal used is E. Look out for the following features that are incorporated in most modern programmable heat pump thermostat. Low voltage checking that prompts you that the incoming power is low. Error codes that tell you the reason why your system is not running properly. 3 minutes mininum compressor off time to prevent the short cycling of compressor. Short cycling of compressor will shorten its lifetime. Programmable day and night settings of the set temperature.
Weekends settings and setback functions for vacations. Ability to check the status of the thermostat and control the settings remotely via smart phones or computer.
![York air conditioner wiring guide York air conditioner wiring guide](/uploads/1/2/3/8/123809060/337501495.jpg)
The presence of this feature will raise the cost of the thermostat.
In Article ' ', which was the first Article in our new Course HVAC-2: Electrical Rules and Calculations for Air-Conditioning Systems, I explained the following points:. Introduction for Air-Conditioning Systems Types,. Introduction for Types of Motors/Compressors used in Air-Conditioning Systems. And in Article ' ', I explained the following points:.
Importance of Electrical Wiring for Air Conditioning Systems,. How to get the Electrical Wiring for Air Conditioning systems?,.
Types of Electrical Wiring Diagrams For Air Conditioning Systems,. How to read Electrical Wiring Diagrams? Today, I will explain Electrical Wiring for different Air-Conditioning Systems Types and Equipment. A rotating selector/Mode switch marked with a hot-cold scale of five positions (off, high cool, low cool, high fan, low fan) with no temperature settings. A rotating Thermostat switch work as on/off switch for the compressor, its status is depending on what temperature/cooling degree you set it at (usually there are 8 positions for cooling degree).
Louvers swing switch: it is on/off switch which controls the swing motor responsible for controlling the movement and direction angle in which the air be supplied from the louvers to the room. The branch circuit will originate from one of the single pole/three pole Overcurrent protective device OCPD included in an electrical panel. Then go through raceway system (conduits, ducts, ) to a disconnect means of some type suitable for the application. After that, the main power cord of the split air conditioning unit is connected to this disconnecting means from one side, the other side is connected to the terminal box in the indoor unit (see Fig.9) or in the outdoor unit (see Fig.10)according to the manufacturer’s recommendations and wiring diagrams. Unitary packaged systems (see Fig.28) are by far the most commonly used air conditioning equipment in commercial buildings.
![York York](/uploads/1/2/3/8/123809060/584308548.png)
A packaged air conditioning unit is a self-contained air conditioner. It provides the cooling, heating and the motion of the air. All the components needed for cooling, heating, and air movement are assembled in a steel casing.
Most packaged units use semi hermetic compressors which mean that the motor and compressor unit are mounted in one housing. Fig.28: Rooftop packaged units Construction. Unitary Packaged units are packaged units which come as one single package that is ready to be mounted on a rooftop or on ground floor for some types. Rooftop packaged units can be classified according to the type of heating they supply. There are rooftop packed units with either electric heating or gas-fired heating.
The heating can also be provided by a heat pump. However, electric heat and gas-fired furnaces are mainly used. The available cooling capacity of common packaged rooftop units ranges from 10 kW (3 tons) to 850 kW (241 tons). The air flow rate covers a range from 400 l/s (850 ft3/min) to 37,800 l/s (80,000 ft3/min).